Digital health

Integrating with the Healthcare Identifiers Service

Separate developer access, Notice of Connection, conformance testing and customer certificate setup when planning an HI Service integration.

Healthcare identifiers sit behind everyday clinical and administrative workflows.

Start with the patient, individual provider or provider organisation the workflow needs to identify. Name the record and the role authorised to confirm or correct it; the identifier types are set out below.

Services Australia manages Notice of Connection testing. The Australian Digital Health Agency manages conformance testing. The developer guidance describes both mandatory testing stages for products developed or updated to connect to the HI Service.

WorkstreamWhat the project needs to establish
Developer accessAn authorised organisation contact, portal registration and access to the required resources
ImplementationApplicable use cases, identifier handling and defined responses to service outcomes
Connection testingA completed NOC process and records of vendor ID, product name and version
ConformanceThe applicable requirements, evidence and assessment arrangements
Customer onboardingOrganisation credentials, permissions and a repeatable setup process
A Healthcare Provider Identifier confirmation step in ScriptStream.

Know which identifier the workflow needs

The service distinguishes individuals receiving healthcare, individual healthcare providers and provider organisations. These use an Individual Healthcare Identifier (IHI), Healthcare Provider Identifier–Individual (HPI-I) and Healthcare Provider Identifier–Organisation (HPI-O), respectively.

A patient identifier is not interchangeable with a provider identifier. Map each identifier to the record it belongs to and the decisions it supports. Ask what the application should do when a search returns an unexpected result or the available details do not support a confident match.

Treat the lookup as one step in the clinical or administrative task, with its other conditions still to be checked.

Separate the access and testing stages

Services Australia's developer guidance describes organisation registration through the Health Systems Developer Portal, access to licensed material and the development environment, followed by product testing.

Notice of Connection checks the connection to the service. Conformance testing addresses safe implementation and use of identifiers. Both are mandatory for products developed or updated to connect; Services Australia recommends completing connection testing first. It also recommends conformance testing for products that use identifiers without a direct connection.

A service view connects specialist roles, external systems and follow-up responsibilities. It is an operating model, not the HI Service's formal architecture.

Design identity handling for ordinary mistakes

Test missing details, changed details and results that require a person to investigate. Make it clear when users should correct a record, repeat a search or seek help. A system that accepts any returned value without showing its context can create a misleading sense of certainty.

Preserve enough history to explain how a record was matched. Limit the personal information in technical logs, and make access to investigation tools appropriate to the support role. Confirm the legal basis for collecting, using and disclosing identifiers for the particular workflow.

Do not turn a short assessment estimate into a delivery commitment. The overall schedule also depends on development readiness, access, test data, issue correction and assessor availability.

Make certificate setup part of onboarding

Production credentials and certificates need an owner at the healthcare organisation. Confirm the applicable authentication arrangements with the service and the customer's authorised administrator. The developer's test access is not a substitute for a customer's production setup.

Record how credentials are installed, protected, renewed and replaced. Include a test for an unavailable or expired credential, so the user sees a useful next step and support staff can identify the cause.

Keep the integration within the whole product plan

The ScriptStream customer story records completed HI Notice of Connection and conformance work within a broader prescribing programme. Twin Global developed the platform for Wesley Pharmacy Group.

For another product, start with a dependency map showing identifiers, prescribing, authentication and any other national services. Give each dependency its own acceptance evidence. This makes it easier to see which integration is ready and which still blocks a complete user journey.

Discuss a healthcare identifiers integration